Anti-islanding relay UFR1001E ( Ziehl )
The UFR1001E boasts a dual-channel configuration, providing a fault-proof system. This redundancy ensures continuous monitoring even in the event of a fault in one channel, enhancing the overall reliability of the relay.
R13,373.72 Original price was: R13,373.72.R12,163.29Current price is: R12,163.29. inc.Vat
3 in stock (can be backordered)
Sale Ends In:
Secure SSL Encrypted Payment
Fast Shipping
3-5 Days
Price Match
Send Your Quote
Price Lock
Available online only
Easy Returns
30 day Policy
Introducing the Anti-Islanding Relay UFR1001E by Ziehl for Victron Inverters, an essential component to secure NRS approval for installations utilizing non-compliant inverters with NRS regulations. The UFR1001E is a state-of-the-art dual-channel device designed to monitor voltage and frequency in electricity generation plants, ensuring a reliable and safe operation.
Key Features:
- Dual-Channel Redundancy: The UFR1001E boasts a dual-channel configuration, providing a fault-proof system. This redundancy ensures continuous monitoring even in the event of a fault in one channel, enhancing the overall reliability of the relay.
- Output Relay and Switch Monitoring: The device allows for the monitoring of output relays and connected switches through feedback contacts. In the event of a switch failure to either turn on or off, the UFR1001E takes corrective actions to maintain the integrity of the monitored plant.
- Voltage Monitoring:
- Under and overvoltage monitoring ranging from 15 to 520 V.
- Option for measuring phase-neutral or phase-phase voltages, offering flexibility in diverse electrical configurations.
- Frequency Monitoring:
- Under and over-frequency monitoring spanning 45 to 65 Hz.
- Robust monitoring of the rate of change of frequency (ROCOF) within the range of 0.100 to 5,000 Hz/s, ensuring precise control.
- Quality of Voltage Monitoring:
- Continuous monitoring of the quality of voltage through a 10-minute average, contributing to the stability and reliability of the electricity generation plant.
- Vector Shift Monitoring:
- Monitoring of vector shift in the range of 2 to 65 degrees, allowing for a comprehensive assessment of the electrical parameters.
- Zero Voltage Monitoring (ANSI 59v0):
- Robust monitoring of zero voltage (U0) according to ANSI standards, further enhancing the protective features of the relay.
- Passive Anti-Islanding Protection:
- Adheres to chapter 6.5.3 and appendix D2 specifications, providing passive anti-islanding protection to meet regulatory requirements.
- South Africa Certification:
- The UFR1001E comes with a Certificate of Conformity (NRS 097-2-1:2010 1.0), attesting to its compliance with South African standards and regulations.
Important Notice:
Shop Solar relies on relevant suppliers/manufacturers and/or third parties to provide adequate information. Errors and omissions are possible.
Lead Time:
- 3- 5 Business days
Important:
This product requires professional installation by a qualified electrician or technician. It is imperative that all installations strictly adhere to local wiring regulations and standards. Please ensure that the installation is carried out by a certified professional to guarantee the safety and proper functioning of the system. Shop Solar holds no responsibility for any product malfunctions that may arise due to incorrectly installed systems. Your safety and the optimal performance of the product are our top priorities. Warranty is only valid when the product is installed by a certified electrician and a CoC is issued.
Brand |
Victron Energy |
---|
You must be logged in to post a review.
Introducing the Anti-Islanding Relay UFR1001E by Ziehl for Victron Inverters, an essential component to secure NRS approval for installations utilizing non-compliant inverters with NRS regulations. The UFR1001E is a state-of-the-art dual-channel device designed to monitor voltage and frequency in electricity generation plants, ensuring a reliable and safe operation.
Key Features:
- Dual-Channel Redundancy: The UFR1001E boasts a dual-channel configuration, providing a fault-proof system. This redundancy ensures continuous monitoring even in the event of a fault in one channel, enhancing the overall reliability of the relay.
- Output Relay and Switch Monitoring: The device allows for the monitoring of output relays and connected switches through feedback contacts. In the event of a switch failure to either turn on or off, the UFR1001E takes corrective actions to maintain the integrity of the monitored plant.
- Voltage Monitoring:
- Under and overvoltage monitoring ranging from 15 to 520 V.
- Option for measuring phase-neutral or phase-phase voltages, offering flexibility in diverse electrical configurations.
- Frequency Monitoring:
- Under and over-frequency monitoring spanning 45 to 65 Hz.
- Robust monitoring of the rate of change of frequency (ROCOF) within the range of 0.100 to 5,000 Hz/s, ensuring precise control.
- Quality of Voltage Monitoring:
- Continuous monitoring of the quality of voltage through a 10-minute average, contributing to the stability and reliability of the electricity generation plant.
- Vector Shift Monitoring:
- Monitoring of vector shift in the range of 2 to 65 degrees, allowing for a comprehensive assessment of the electrical parameters.
- Zero Voltage Monitoring (ANSI 59v0):
- Robust monitoring of zero voltage (U0) according to ANSI standards, further enhancing the protective features of the relay.
- Passive Anti-Islanding Protection:
- Adheres to chapter 6.5.3 and appendix D2 specifications, providing passive anti-islanding protection to meet regulatory requirements.
- South Africa Certification:
- The UFR1001E comes with a Certificate of Conformity (NRS 097-2-1:2010 1.0), attesting to its compliance with South African standards and regulations.
Important Notice:
Shop Solar relies on relevant suppliers/manufacturers and/or third parties to provide adequate information. Errors and omissions are possible.
Lead Time:
- 3- 5 Business days
Important:
This product requires professional installation by a qualified electrician or technician. It is imperative that all installations strictly adhere to local wiring regulations and standards. Please ensure that the installation is carried out by a certified professional to guarantee the safety and proper functioning of the system. Shop Solar holds no responsibility for any product malfunctions that may arise due to incorrectly installed systems. Your safety and the optimal performance of the product are our top priorities. Warranty is only valid when the product is installed by a certified electrician and a CoC is issued.